II. What Is Class D Amplification? (cont?d.)
Protect
only
triggers mute
Figure 17.
Base of Q10 goes low. Voltage at Q10 goes up, turning on Q7.
This then puts the amp in mute.
Remember!
Protection is only
MUTE (standby mode).
Figure 18.
Harman Consumer Group 250 Crossways Park Dr. Woodbury, New York 11797
Email
[email protected] Web www.harmanservice.com